Standard Construction Specifications Part 2 Abu Dhabi May 2026

: Coordination and protection of existing services within the road right-of-way. Landscaping and Irrigation

Part 2, Section 1.6.2 states that cement must be stored on raised timber platforms under a waterproof cover, off the ground. The Violation: Storing cement bags directly on sand or steel pallets. Fix: Build dedicated cement sheds with hygrometers; humidity must stay below 60%. standard construction specifications part 2 abu dhabi

| | Source | Acceptance Criteria | |------------------|------------|--------------------------| | Selected fill | Borrow pit (approved quarry, e.g., Al Ain or Sweihan) | Max particle size 75 mm, ≤ 5% fines passing #200, sulfate content ≤ 0.5% by weight | | Granular sub-base | Same | CBR ≥ 30, sand equivalent ≥ 35, liquid limit ≤ 25, plasticity index ≤ 6 | | Structural fill | On-site or imported | No organic matter, no gypsum bands, chloride ≤ 0.3% (for reinforced zone) | | Fill behind retaining walls | Free-draining granular material | ≤ 12% passing #200 sieve | : Coordination and protection of existing services within

and the Department of Municipalities and Transport (DMT). While Part 1 focuses on general road works, Part 2 typically addresses more specialized Road Structures and detailed product requirements TAMM - Abu Dhabi Government Services 1. Scope and Technical Framework The "Part 2" designation is most commonly associated with Volume 2: Road Structures (TR-542-2) Fix: Build dedicated cement sheds with hygrometers; humidity

This is the most distinct feature. Standard international codes (like those in the UK or US) do not account for the aggressive saline groundwater and extreme heat of the UAE. Part 2 includes specific clauses regarding: